STAR
Cal STAR — firmware, DAQ server, and engine design
|
Static Public Attributes | |
| str | name = Field(min_length=1, description="What the component is, e.g. '1/2 in ball valve'.") |
| float | K = Field(ge=0, description="Loss coefficient on the line velocity head [-].") |
| str | source = Field(min_length=1, description="Where K came from (Crane TP-410 A-27, datasheet Cv, water-flow test, ...).") |
One itemised loss in a feed run: a valve, bend, tee, filter or fitting. ``K`` is in velocity heads of the LINE (A_hydraulic), so a component in a different bore must be referred first: K_line = K_local (A_line / A_local)^2 (scripts/feed_line_K.py). ``source`` is required -- a loss coefficient with no provenance is the thing this list exists to replace.
Definition at line 296 of file config_schemas.py.
|
static |
Definition at line 305 of file config_schemas.py.
|
static |
Definition at line 304 of file config_schemas.py.
|
static |
Definition at line 306 of file config_schemas.py.