STAR
Cal STAR — firmware, DAQ server, and engine design
|
Public Member Functions | |
| float | outlet_setpoint (self, float mdot, FlowConditions flow) |
| float | pressure_drop (self, float mdot, FlowConditions flow) |
| bool | is_saturated (self, float mdot, FlowConditions flow) |
| Public Member Functions inherited from feedtwin.comps.regulator.Regulator | |
| float | commanded_setpoint (self, FlowConditions flow) |
| float | supply_effect (self, FlowConditions flow) |
| float | lockup_pressure (self, FlowConditions|None flow=None) |
| float|None | seat_capacity (self, FlowConditions flow, float xT=XT_TYPICAL) |
| float|None | pinned_flow (self, float dp_available, FlowConditions flow) |
| dict[str, object] | seat_model (self, float xT=XT_TYPICAL) |
| float | total_dp (self, float mdot, FlowConditions flow) |
| float|None | flow_ceiling (self, FlowConditions flow) |
| bool | is_choked (self, float dp_available, FlowConditions flow) |
| dict[str, float] | diagnostics (self, float mdot, FlowConditions flow) |
| list[Violation] | check (self) |
| list[Violation] | envelope_violations (self, float mdot, FlowConditions flow) |
| Public Member Functions inherited from feedtwin.comps.base.HydraulicComponent | |
| None | __init__ (self, ComponentInstance instance) |
| str | id (self) |
| str | type (self) |
| float | static_head (self, FlowConditions flow) |
| float | signal (self, FlowConditions flow, str name, float default=1.0) |
| bool | isolates (self, Mapping[str, float]|None signals=None) |
| int | n_residuals (self) |
| Sequence[float] | residuals (self, EvalContext ctx) |
| Mapping[str, float] | outputs (self, EvalContext ctx) |
| FlowConditions | conditions (self, PortState port, Mapping[str, float] signals) |
| str | __repr__ (self) |
Additional Inherited Members | |
| Public Attributes inherited from feedtwin.comps.base.HydraulicComponent | |
| instance = instance | |
| p = instance.si_params() | |
| opt = dict(instance.options) | |
| Static Public Attributes inherited from feedtwin.comps.base.HydraulicComponent | |
| str | inlet_port = "inlet" |
| str | outlet_port = "outlet" |
| bool | symmetric = False |
| conditions_provider = None | |
| Protected Member Functions inherited from feedtwin.comps.regulator.Regulator | |
| GasCv|None | _gas_seat (self, FlowConditions flow) |
| float | _seat_dp (self, float magnitude, FlowConditions flow) |
| float | _creep (self, float magnitude) |
| float | _rated_multiple (self, float mdot) |
Perfect setpoint, unlimited capacity. For sanity checks and first passes. Kept as a *named model* rather than a regulator with zero coefficients so that a report can distinguish "we chose not to model droop" from "nobody filled in the droop". Those look identical in the numbers and are very different in what they mean.
Definition at line 632 of file regulator.py.
| bool feedtwin.comps.regulator.IdealRegulator.is_saturated | ( | self, | |
| float | mdot, | ||
| FlowConditions | flow ) |
Whether the regulator has run out of authority at this operating point. True means the outlet is being set by the seat rather than by the setpoint -- the regulator is wide open and no longer regulating. Worth surfacing loudly: the pressure it reports is still a real number, and it is no longer the number anybody designed for.
Reimplemented from feedtwin.comps.regulator.Regulator.
Definition at line 647 of file regulator.py.
| float feedtwin.comps.regulator.IdealRegulator.outlet_setpoint | ( | self, | |
| float | mdot, | ||
| FlowConditions | flow ) |
The pressure this regulator is trying to hold right now [Pa].
Reimplemented from feedtwin.comps.regulator.Regulator.
Definition at line 641 of file regulator.py.
References feedtwin.comps.regulator.Regulator.commanded_setpoint().
| float feedtwin.comps.regulator.IdealRegulator.pressure_drop | ( | self, | |
| float | mdot, | ||
| FlowConditions | flow ) |
Flow-dependent pressure loss [Pa]. Always non-negative. A *loss*: it opposes the flow, so it lowers the downstream pressure whichever way the fluid is going. Reverse flow is each component's own business -- symmetric for a pipe, very much not for a check valve. Anything that does **not** depend on the direction of flow belongs in :meth:`static_head`, not here. See that method for why the distinction is load-bearing rather than tidy.
Reimplemented from feedtwin.comps.regulator.Regulator.
Definition at line 644 of file regulator.py.
References feedtwin.comps.regulator.Regulator.commanded_setpoint(), and max.