STAR
Cal STAR — firmware, DAQ server, and engine design
|
Public Member Functions | |
| None | __init__ (self, ComponentInstance instance, InjectorSide side) |
| str | id (self) |
| float | effective_area (self, float mdot, FlowConditions flow) |
| float | pressure_drop (self, float mdot, FlowConditions flow) |
| bool | off_card (self, float mdot, FlowConditions flow) |
| dict[str, float] | diagnostics (self, float mdot, FlowConditions flow) |
| list[Violation] | check (self) |
| Public Member Functions inherited from feedtwin.comps.base.HydraulicComponent | |
| None | __init__ (self, ComponentInstance instance) |
| str | type (self) |
| float | static_head (self, FlowConditions flow) |
| float | total_dp (self, float mdot, FlowConditions flow) |
| float | signal (self, FlowConditions flow, str name, float default=1.0) |
| bool | isolates (self, Mapping[str, float]|None signals=None) |
| float|None | flow_ceiling (self, FlowConditions flow) |
| float|None | pinned_flow (self, float dp_available, FlowConditions flow) |
| bool | is_choked (self, float dp_available, FlowConditions flow) |
| int | n_residuals (self) |
| Sequence[float] | residuals (self, EvalContext ctx) |
| Mapping[str, float] | outputs (self, EvalContext ctx) |
| FlowConditions | conditions (self, PortState port, Mapping[str, float] signals) |
| str | __repr__ (self) |
Public Attributes | |
| side = side | |
| Public Attributes inherited from feedtwin.comps.base.HydraulicComponent | |
| instance = instance | |
| p = instance.si_params() | |
| opt = dict(instance.options) | |
Additional Inherited Members | |
| Static Public Attributes inherited from feedtwin.comps.base.HydraulicComponent | |
| str | inlet_port = "inlet" |
| str | outlet_port = "outlet" |
| bool | symmetric = False |
| conditions_provider = None | |
One propellant's path through the injector face. ``dp = mdot^2 / (2 rho (Cd A)^2)`` -- the orifice relation, with ``Cd`` coming from the Reynolds-dependent model in the engine config rather than being a constant. That dependence is not decoration: at low flow during startup the discharge coefficient is materially below its high-Reynolds value, and an injector modelled at a fixed ``Cd`` opens too fast. Built from an :class:`~feedtwin.engine.design.InjectorSide` rather than from a component config, because the whole point of Phase 08 is that these numbers arrive from Layer 1 and are not retyped.
Definition at line 49 of file component.py.
| None feedtwin.engine.component.InjectorLeg.__init__ | ( | self, | |
| ComponentInstance | instance, | ||
| InjectorSide | side ) |
| list[Violation] feedtwin.engine.component.InjectorLeg.check | ( | self | ) |
Design limits this component's configuration breaks. Configuration only -- nothing here depends on the operating point, so it can be run the moment a network is loaded and long before it is solved. Bend radius is the case that motivated it: a line bent tighter than its tube allows is a fabrication problem, and finding out at the bender is expensive.
Reimplemented from feedtwin.comps.base.HydraulicComponent.
Definition at line 134 of file component.py.
References _USBD_HandleTypeDef.id, anonymous_namespace{idle_e2e.cpp}::Check.id, check_t.id, feedtwin.comps.elements.OrificeISO5167.id, feedtwin.comps.gas.GasOrifice.id, feedtwin.comps.manifold.Manifold.id, feedtwin.comps.regulator.Regulator.id, feedtwin.comps.relief.ReliefValve.id, id, and side.
| dict[str, float] feedtwin.engine.component.InjectorLeg.diagnostics | ( | self, | |
| float | mdot, | ||
| FlowConditions | flow ) |
Derived quantities worth reporting: velocity, Reynolds number, K. Never consumed by a solver. This is what a frame and a report show, and what makes a result inspectable rather than just a number.
Reimplemented from feedtwin.comps.base.HydraulicComponent.
Definition at line 116 of file component.py.
References feedtwin.engine.balance.SideBalance.effective_area(), effective_area(), off_card(), feedtwin.comps.base.HydraulicComponent.pressure_drop(), and side.
| float feedtwin.engine.component.InjectorLeg.effective_area | ( | self, | |
| float | mdot, | ||
| FlowConditions | flow ) |
``Cd . A`` at this operating point [m^2]. With an engine card it is recovered from the card's pressure drop at the density this leg sees, so the diagnostics and the mixture balance read the same injector the solve used.
Definition at line 71 of file component.py.
References side.
Referenced by diagnostics(), and pressure_drop().
| str feedtwin.engine.component.InjectorLeg.id | ( | self | ) |
Reimplemented from feedtwin.comps.base.HydraulicComponent.
Definition at line 68 of file component.py.
References feedtwin.comps.base.HydraulicComponent.instance.
Referenced by feedtwin.model.component.ComponentInstance.to_dict().
| bool feedtwin.engine.component.InjectorLeg.off_card | ( | self, | |
| float | mdot, | ||
| FlowConditions | flow ) |
True when this lookup is outside the hull the leg's card was fitted to. The card's table clamps outside its box, which keeps the number physical and says nothing; the hull is how a trace learns it left what the card knows (:func:`fold_injectors`). No card, nothing to be off.
Definition at line 104 of file component.py.
References side.
Referenced by diagnostics().
| float feedtwin.engine.component.InjectorLeg.pressure_drop | ( | self, | |
| float | mdot, | ||
| FlowConditions | flow ) |
Flow-dependent pressure loss [Pa]. Always non-negative. A *loss*: it opposes the flow, so it lowers the downstream pressure whichever way the fluid is going. Reverse flow is each component's own business -- symmetric for a pipe, very much not for a check valve. Anything that does **not** depend on the direction of flow belongs in :meth:`static_head`, not here. See that method for why the distinction is load-bearing rather than tidy.
Reimplemented from feedtwin.comps.base.HydraulicComponent.
Definition at line 84 of file component.py.
References feedtwin.engine.balance.SideBalance.effective_area(), effective_area(), and side.
| feedtwin.engine.component.InjectorLeg.side = side |
Definition at line 65 of file component.py.
Referenced by check(), diagnostics(), effective_area(), off_card(), and pressure_drop().