STAR
Cal STAR — firmware, DAQ server, and engine design
|
Public Member Functions | |
| None | test_no_flow_no_heat (self) |
| None | test_warm_wall_warms_cold_gas (self) |
| None | test_cold_wall_cools_warm_gas (self) |
| None | test_gas_never_overshoots_the_wall (self) |
| None | test_more_flow_means_less_warming_per_kilogram (self) |
| None | test_more_metal_area_means_more_pickup (self) |
| None | test_heat_agrees_with_the_temperature_rise (self) |
| None | test_reverse_flow_is_treated_by_magnitude (self) |
| None | test_laminar_uses_a_fixed_nusselt (self) |
| None | test_missing_property_is_not_a_crash (self, str bad) |
Definition at line 74 of file test_wall.py.
| None test_wall.TestExchange.test_cold_wall_cools_warm_gas | ( | self | ) |
Runs both ways. A LOX-cold line chills the gas put through it, which is the chilldown of a downstream fitting rather than a special case.
Definition at line 96 of file test_wall.py.
References test_wall.a_line(), and exchange().
| None test_wall.TestExchange.test_gas_never_overshoots_the_wall | ( | self | ) |
Effectiveness is bounded by one, so the stream can approach the metal and never pass it, whatever the geometry.
Definition at line 105 of file test_wall.py.
References test_wall.a_line(), and exchange().
| None test_wall.TestExchange.test_heat_agrees_with_the_temperature_rise | ( | self | ) |
Q = mdot.cp.dT, or the wall's book-keeping does not close.
Definition at line 137 of file test_wall.py.
References test_wall.a_line(), and exchange().
| None test_wall.TestExchange.test_laminar_uses_a_fixed_nusselt | ( | self | ) |
Below the laminar limit Dittus-Boelter does not apply. It is not merely inaccurate there -- it tends to zero with flow, so a trickle would come out predicting no heat transfer at all, when the real answer is the fully-developed laminar value.
Definition at line 158 of file test_wall.py.
References test_wall.a_line(), and exchange().
| None test_wall.TestExchange.test_missing_property_is_not_a_crash | ( | self, | |
| str | bad ) |
A property gap must cost the line its heat, not the tick its life.
Definition at line 172 of file test_wall.py.
References test_wall.a_line(), and exchange().
| None test_wall.TestExchange.test_more_flow_means_less_warming_per_kilogram | ( | self | ) |
NTU falls as mdot rises: a faster stream has less residence time, so each kilogram picks up less even though the total heat goes up.
Definition at line 115 of file test_wall.py.
References test_wall.a_line(), and exchange().
| None test_wall.TestExchange.test_more_metal_area_means_more_pickup | ( | self | ) |
Definition at line 128 of file test_wall.py.
References test_wall.a_line(), and exchange().
| None test_wall.TestExchange.test_no_flow_no_heat | ( | self | ) |
The single most important guard in this file. With no flow there is no convection, and a wall that leaked heat into a stationary node would warm a stand that is just sitting there -- which is the soak model this deliberately does not have, arriving by the back door and wrong.
Definition at line 75 of file test_wall.py.
References test_wall.a_line(), and exchange().
| None test_wall.TestExchange.test_reverse_flow_is_treated_by_magnitude | ( | self | ) |
A negative mdot is the solver's sign convention, not a different physical situation; the line still picks up heat from its metal.
Definition at line 146 of file test_wall.py.
References test_wall.a_line(), and exchange().
| None test_wall.TestExchange.test_warm_wall_warms_cold_gas | ( | self | ) |
Definition at line 89 of file test_wall.py.
References test_wall.a_line(), and exchange().