STAR
Cal STAR — firmware, DAQ server, and engine design
|
Public Member Functions | |
| None | test_half_inch_tube_mass_is_right (self) |
The tube's own metal, which is the part a drawing can compute.
Definition at line 181 of file test_wall.py.
| None test_wall.TestMassFromGeometry.test_half_inch_tube_mass_is_right | ( | self | ) |
1/2 in. x 0.035 in. wall 316: about 265 g/m, so 255 mm is ~67 g -- against roughly 200 g for the two unions holding it on. The fittings dominating the tube is the reason `fitting_mass` exists at all.
Definition at line 184 of file test_wall.py.