STAR
Cal STAR — firmware, DAQ server, and engine design
|
Public Member Functions | |
| None | test_the_room_is_negligible_over_a_burn (self) |
| None | test_the_lines_own_metal_is_not (self) |
| None | test_the_metal_runs_out (self) |
The numbers behind the answer given to the stand's own observation. Two paths could warm the gas: the room, through frost and the tube wall (Path B), and the line's own thermal mass (Path A). Only one of them is worth modelling, and the arithmetic here is why.
Definition at line 195 of file test_wall.py.
| None test_wall.TestTheIcicleQuestion.test_the_lines_own_metal_is_not | ( | self | ) |
Path A. The same stream through 0.4 kg of room-temperature steel picks up kelvins, not hundredths -- an order of magnitude that decides which one gets a model.
Definition at line 215 of file test_wall.py.
References test_wall.a_line(), and exchange().
| None test_wall.TestTheIcicleQuestion.test_the_metal_runs_out | ( | self | ) |
And it is a first-run effect. The wall has a fixed number of joules in it; spend them and the second run of the day starts colder, because only the room recharges it and the room is Path B.
Definition at line 226 of file test_wall.py.
References test_wall.a_line().
| None test_wall.TestTheIcicleQuestion.test_the_room_is_negligible_over_a_burn | ( | self | ) |
Path B. Still air onto 0.4 m^2 of cold pipe is a few watts; even a generous frosted-surface figure is tens. Against a 150 g/s stream that is hundredths of a kelvin -- so the room is not what warms the gas.
Definition at line 203 of file test_wall.py.