How to add a new sensor type so data flows from hardware to the frontend GUI.
Each sensor type gets a VTable ID — a two-byte tuple [high, low] that uniquely identifies the data stream in Elodin. The relay must subscribe to each VTable ID it wants to receive.
| High | Low Range | Type | Component | Layout |
|---|---|---|---|---|
| 0x10 | 0x01-0x40 | Board heartbeats | - | Custom |
| 0x20 | 0x01-0x0E | PT raw | raw_adc_counts | 21 bytes |
| 0x20 | 0x11-0x1E | PT calibrated | pressure_psi | 21 bytes |
| 0x21 | 0x01-0x20 | TC raw | raw_adc_counts | 21 bytes |
| 0x21 | 0x11-0x24 | TC calibrated | temperature_c | 21 bytes |
| 0x22 | 0x01-0x04 | RTD raw | raw_resistance | 21 bytes |
| 0x22 | 0x11-0x14 | RTD calibrated | temperature_c | 21 bytes |
| 0x23 | 0x01-0x14 | LC raw | raw_adc_counts | 21 bytes |
| 0x23 | 0x11-0x24 | LC calibrated | force_units | 21 bytes |
| 0x24 | 0x01-0x14 | Encoder raw | raw_adc_counts | 21 bytes |
| 0x24 | 0x11-0x24 | Encoder calibrated | position_deg | 21 bytes |
| 0x25 | 0x01-0xFF (full board ID) | Environmental BME280 | temperature_c, pressure_pa, humidity_rh | 24 bytes |
| 0x30 | 0x01-0x0A | Actuator feedback | raw_adc_counts | 21 bytes |
| 0x31 | 0x01-0x14 | Actuator state (current-sense) | actuator_state | 10 bytes |
| 0x32 | 0x01-0x14 | Actuator commanded state | actuator_state_commanded | 10 bytes |
| 0x40 | 0x00 | Controller actuation | - | 19 bytes |
| 0x41 | 0x00 | Controller diagnostics | - | 62 bytes |
| 0x42 | 0x00 | Controller measurement | - | 80 bytes |
| 0x43 | 0x00 | PSM state transition | - | 11 bytes |
| 0x44 | 0x00 | FIRE state | - | 18 bytes |
| 0x46 | 0x00 | CalibrationCommand (backend → calibration_service) | type + sensor_id + reference_value | 16 bytes |
| 0x50 | 0x00 | SequencerState | state + bitmask + debug | 17 bytes (see below) |
| 0x50 | 0x60-0x66 | PSM actuator commands | - | 15 bytes |
| 0x60 | 0x01-0xFF | Self-test results | sensor_id + result | 10 bytes |
Raw vs Calibrated convention: Raw channels use low = channel_id (1-based). Calibrated channels use low = 0x10 + channel_id. Example: PT channel 3 raw = [0x20, 0x03], calibrated = [0x20, 0x13].
Free high bytes, if you need a new stream: 0x45, 0x47–0x4F, 0x51–0x5F. Anything >= 0x80 is off limits: by convention a high byte of 0x80 or above is a VTable registration ACK rather than data, and calibration_main.cpp reads it that way (see its type_hi < 0x80 packet filter). Add a row here when you take one, or the next person reads a stale map (this table sat without 0x24 and 0x46 for a while, which is how you end up debugging a collision instead of picking a free byte).
The BME280 firmware sends packet type 13 to UDP port 5006 at 5 Hz. lib/daq-protocol/src/DiabloPacketUtils.h provides the parser. SensorFramePipeline decodes the packet, and daq_bridge resolves its source IP against enabled ENVIRONMENTAL boards before publishing it. Unknown sources, disabled boards, wrong protocol versions, incorrect packet lengths, non-finite values, humidity outside 0–100 RH, and zero pressure do not produce rows.
Each board has one BME280 on logical connector 1. Configure active_connectors = [1]; an empty list disables its data stream. The firmware streams on its own and does not use SENSOR_CONFIG or ADC calibration. The readings already use °C, absolute Pa, and RH. The bridge preserves the pressure as uint32, including its units.
Environmental tables use the full board ID as the low byte, rather than the channel-slot scheme. Board 25 publishes [0x25, 0x19] under entity ENV25. Board 35 publishes a separate ENV35 entity. There is no raw/calibrated pair.
Enabled environmental boards need distinct integer IDs from 1 to 255. The shared configuration validator reports invalid IDs and duplicate IDs as errors. The C++ loader rejects them before narrowing an ID to a byte, and the bridge exits with a configuration error before connecting to the database. Disabled environmental boards do not claim IDs.
| Offset | Type | Component |
|---|---|---|
| 0 | u64 | timestamp_ns (server arrival time, Unix epoch) |
| 8 | f32 | temperature_c |
| 12 | u32 | pressure_pa (absolute) |
| 16 | f32 | humidity_rh |
| 20 | u32 | sample_ts_ms (firmware clock) |
EnvironmentalMessage, DatabaseConfig::register_environmental_tables(), and parseElodinPacket() must agree on this 24-byte layout. The bridge registers the schema at startup and after reconnecting. The backend and relay subscribe using enabled boards in the deployed configuration, then emit three SENSOR_UPDATE values with a shared timestamp.
The tracked config/config_base.toml and config/profiles/default/config.toml include board 25 at 192.168.2.25, matching firmware/Environmental Tracker/src/main.h. config/config.toml is a generated, gitignored runtime file. For an existing installation, copy [boards.environmental_board] into its active profile and deploy that profile. The Environmental view is available under All Views → Environmental, at /environmental, and can be pinned with environmental in [gui].tabs. It shows separate readouts and plots for each measurement; stale readouts show “Waiting for fresh data.” Heartbeats appear in Boards.
The board simulator supports --only-type ENVIRONMENTAL with the firmware's 5 Hz default rate. Use a loopback simulation config for local testing. The standard test/ws_data_flow_test.ts suite includes environmental values, units, epoch timestamps, heartbeat attribution, and malformed-packet rejection. Select these checks with --backend=thin --only=environmental against an existing test stack. The default packet source is 127.0.0.25; TEST_ENVIRONMENTAL_SOURCE_IP overrides it for isolated tests.
To test subscription retry and database restart recovery without hardware, build daq_bridge, install the backend dependencies, then run from diablo_server/backend:
This test starts an isolated Elodin database, bridge, and backend on local ports. The bridge also requires its existing UDP config port 5008 to be free. It waits for Elodin to reject the environmental subscription before starting the bridge, runs the standard environmental checks, then replaces the database with a fresh instance and runs those checks again without restarting the bridge or backend. It also checks that invalid and duplicate environmental IDs make the bridge exit with status 1. The test stops its processes on exit.
CI runs backend and frontend unit tests, the C++ environmental configuration test, the standard data-flow suite, and the recovery test. npm test in the backend excludes compiled test copies under dist. The environmental Playwright test uses the live guitest stack and checks readouts and plotted traces on desktop and mobile. The Boards page shows environmental self-tests as N/A because the firmware does not support them. These tests use simulated packets, not physical hardware; a hardware check is still required before merging.
The one operator-command channel into calibration_service. Strictly one-way: the service subscribes and never publishes a reply, so nothing can wait on an acknowledgement. Callers learn what happened by reading the file the service writes — cubic_calibration.json for captures, lc_tare.json for tares — which is also why a UI must never assume a command landed because it was sent. A command published while the service is down is silently dropped.
Layout (16 bytes, and note byte 9 is covered by no field, so Elodin zeroes it — sensor_id sits at the even offset 10 precisely so its high byte survives, since uid = board_id*100 + connector exceeds 255):
| cmd | name | sensor_id | reference_value | effect |
|---|---|---|---|---|
| 0 | Zero / Zero All | uid, or 0 for all | — | Captures a real 0 reference point into the shared fit. Correct for a vented PT; see the note below for why it is not a load-cell tare. |
| 1 | Capture Reference | uid | reference | Feeds the robust learner only (PT). |
| 2 | Save | — | — | Persists robust adjustments. |
| 3 | Capture cubic point | uid | reference | Legacy; equivalent to 5 without the capture-quality record. |
| 4 | Clear channel | uid | — | Drops points + curve. |
| 5 | Capture point | uid | reference | The unified capture the UI uses; routed by the channel's configured model. |
| 6 | New calibration | uid | — | Unified clear. |
| 7 | Reload live store | — | — | Re-read cubic_calibration.json after the backend swapped a profile. |
| 8 | LC tare | uid, or 0 for all | 0 = set, 1 = clear | Display-only zero for a load cell. Never enters a fit, never reaches control or abort, never changes what Elodin records. |
Why a load-cell tare is command 8 and not command 0. A vented PT genuinely is at 0 psig, so capturing a zero on one is a true reference point and belongs in the shared fit. A load cell holding a tank is not at 0 kg: the same capture would inject a false point, and because the fit is least-squares over every point it would tilt the whole cubic rather than shift its intercept.
The tare is therefore stored as the ADC code it was taken at, never as kilograms — offset_kg in lc_tare.json is a cache the service re-derives on every capture, clear and profile swap. Tare a 20 kg tank against a poor two-point fit that reads it as 18, then improve the fit until the same tank evaluates to 20, and a frozen 18 kg offset would display 2 kg for a tank that never moved. Re-deriving from the code gives 20 − 20 = 0. test/ws_data_flow_test.ts's cal_lc_tare check proves this through the full stack; diablo_server/lib/test/test_lc_tare.cpp pins the store.
All raw and calibrated sensor messages use this layout:
Elodin DB validates each VTable row’s byte offsets. In practice:
If alignment is wrong, publishes may succeed at the TCP layer but Elodin will not stream TABLE rows for that packet id — subscribers see nothing (silent failure). The SequencerState case below is the canonical example.
Same rule as above, applied after timestamp_ns (u64 ends at offset 8): the next u32 cannot start at offset 9. Match the 21-byte sensor pattern: u8 at 8, then three padding bytes, then u32 at 12.
An earlier layout packed fields with no gap:
| Field | Offset | Size |
|---|---|---|
| timestamp_ns | 0 | 8 (u64) |
| current_state | 8 | 1 (u8) |
| allowed_bitmask | 9 | 4 (u32) ← misaligned (9 is not a multiple of 4) |
| debug_mode | 13 | 1 (u8) |
Total: 14 bytes on the wire. comms::CommsMessage already serializes fields packed (no hidden C++ struct padding), so the bug was not “wrong sizeof” — it was semantic layout.
Match the sensor pattern: u8 at 8, then three padding bytes, then u32 at 12.
| Field | Offset | Size | Notes |
|---|---|---|---|
| timestamp_ns | 0 | 8 | u64 |
| current_state | 8 | 1 | u8 |
| (padding) | 9 | 3 | Must be present on the wire (zeros); not always listed as separate VTable “schema” fields — see DatabaseConfig.cpp |
| allowed_bitmask | 12 | 4 | u32, 4-byte aligned |
| debug_mode | 16 | 1 | u8 |
Total: 17 bytes. After this change, the relay sees e.g. TABLE [0x50, 0x0] len=17 and thin server can parse and log SequencerState.
If you change this layout, update all of the following in one change set:
The relay still needs [0x50, 0x00] in SENSOR_SUBSCRIPTIONS in elodin-vtable-registry.ts; schema registration for this table is done by the sequencer via DatabaseConfig::register_non_sensor_tables, not necessarily by registerControllerVTables().
diablo_server/lib/src/routing/SensorRouter.cpp
Add a routing function for the new type. This extracts samples from incoming UDP frames and packages them into Elodin messages with the correct VTable ID.
diablo_server/lib/src/elodin/DatabaseConfig.cpp
Register the VTable schemas with Elodin so it accepts TABLE publishes:
diablo_server/backend/src/elodin-vtable-registry.ts
Two things are required in this file, and both must be done or data will silently not flow:
Elodin DB will not accept TABLE publishes or stream data for a VTable ID unless the schema has been registered first. If the DAQ bridge already registers the schema (it does for sensor types 0x20-0x23, 0x30), you can skip this. For other streams, whoever first publishes must register the schema (e.g. SequencerState [0x50, 0x00] is registered by sequencer_service via DatabaseConfig::register_non_sensor_tables — the relay only needs SENSOR_SUBSCRIPTIONS unless you also publish that ID from Node and must register there too).
Add to the vtables array in registerControllerVTables():
If you skip this: Elodin silently ignores the subscription AND the publisher's data. No errors anywhere. This is the hardest bug to diagnose.
Add every [high, low] pair to the SENSOR_SUBSCRIPTIONS array:
This sends VTableStream subscription messages to Elodin when the relay connects. Each subscription is a 2-byte payload [high, low] sent as a MSG packet with a message ID computed from fnv1a("VTableStream").
If you skip this: The relay won't receive the data even though Elodin has it.
VTableStream is NOT lossless (by design). Verified against elodin-db source (libs/db/src/vtable_stream.rs RealTimeStage::next): the streamer task wakes on a write and forwards time_series.latest() — the newest value only. Rows written to the same component while a send is in flight are coalesced away. With multi-chunk board packets (N samples per channel per UDP packet, which real firmware sends via SENSOR_MAX_CHUNKS_BEFORE_SEND), a subscriber typically receives ~1 of N rows per burst. DB storage appends every row regardless — GetTimeSeries/SQL queries see everything; only the live push stream thins. If a consumer ever needs every sample live, elodin-db's FollowStream replication protocol streams contiguous ranges losslessly. Integration Test 15 (ws_data_flow_test.ts) asserts the resulting invariant: at least one row per channel per packet must reach the backend.
diablo_server/backend/src/elodin-protocol.ts
Add parsing logic in the parseElodinPacket() dispatcher function. Use the existing shared helpers for standard 21-byte layouts:
Key: The parseElodinPacket function returns ParsedSensorData[] — an array of { entity, component, value, timestamp } objects. For standard sensors this is a single-element array. For composite packets (like SequencerState) it can be multiple.
If the high byte isn't handled, the packet is silently dropped (or logged if ELODIN_DEBUG=1).
config/config.toml
Add a [sg_roles] section (or similar) mapping channel IDs to names:
diablo_server/backend/src/routes/config.ts
Add a loader function (similar to loadSensorRoleMap) that reads the TOML section and returns a Record<number, string> mapping channel ID → entity name.
diablo_server/backend/src/server.ts
Pass the new entity map to parseElodinPacket via the EntityMaps parameter.
The relay 'packet' handler in server.ts already:
As long as parseElodinPacket returns valid ParsedSensorData, the new sensor will automatically flow to the frontend as SENSOR_UPDATE messages. No routing changes needed.
Exception: If the new data type needs a different MessageType (like STATE_UPDATE or ACTUATOR_UPDATE), add a check for the entity prefix in the packet handler, similar to the _SEQUENCER_STATE block.
diablo_server/shared/types.ts
Add the sensor type to SensorType enum if needed:
diablo_server/frontend/lib/store.ts (ALIASES)
Add alias mappings if the entity names might come in different forms:
Frontend plot component:
No subscription call is needed — DataCache has a single global SENSOR_UPDATE listener that caches ALL entities automatically. TimeSeriesPlot reads from the cache by entity name.
server.ts maintains a Map<string, number> of entityKey → lastBroadcastMs. For each parsed entity update:
This means the backend ingests data at full rate (100+ Hz per sensor) but only sends 10 updates/second per entity to WebSocket clients. The frontend DataCache deduplicates within a 40ms window on its end as well.
The backend and relay call registerVTables() when they connect to Elodin. It builds a deduplicated list from board configuration and fallback streams, then sends each two-byte stream ID in a VTableStream message.
Elodin 0.16.1 rejects a subscription if the publisher has not registered its table. The registry matches the error to the requested stream and retries after 5 seconds, then 10, 20, 40, and up to 60 seconds between attempts. After 12 refusals it stops retrying that stream until the connection resets. A publisher that starts after this limit needs a backend reconnect. Accepted subscriptions stay deduplicated even when no data arrives. Concurrent registration passes share one operation.
The wire request ID is one byte. Each batch uses IDs 1 through 254 once, followed by a read-only GetEarliestTimestamp request on reserved ID 255. Elodin processes these requests in order and sends errors before the timestamp reply. That reply acts as a fence: the registry can reuse request IDs after receiving it without confusing delayed errors with a later batch. If the fence fails or times out, the client closes the connection so retries cannot duplicate subscriptions whose acceptance is unknown.
Missing schema or subscription: C++ publishers register VTable schemas; elodin-vtable-registry.ts subscribes to those tables. Both are required. Check the backend or relay log for subscription rejections. A successful socket write alone does not prove that Elodin accepted the request.
This applies to the C++ subscribers too, and it has already bitten one. heartbeat_service read [0x50, 0x00] and subscribed with a helper called subscribe_stream() whose doc comment promised "all stream data" but which actually sent the calibration service's table list. It received 481 tables it discarded, never [0x50, 0x00], and broadcast engine_state = 0 through every state transition for the life of the process — no error, no CPU, nothing to see. subscribe_stream() is gone; use ElodinClient::subscribe_tables() with fsw::elodin::raw_sensor_tables() / calibrated_sensor_tables() / the kTable* constants in DatabaseConfig.hpp, and name exactly what your service reads.
The integration test (test/test_integration.sh) verifies the full pipeline. New sensor types will automatically appear in Test 1 (Sensor Data Flow) if:
Check the backend log for [Elodin] Unmapped packet id= warnings — set ELODIN_DEBUG=1 to see packets that arrive but have no parser.
With sequencer_service and the thin backend, the integration script also checks that [ThinServer] SequencerState from relay appears in the backend log (proof that [0x50, 0x00] rows are stored in Elodin and relayed). Optional: run with INTEGRATION_SAVE_LOGS=1 to copy integration_*.log to /tmp/integration_logs/ before cleanup (see test/test_integration.sh).