A propellant tank: liquid below, pressurant above, coupled at the surface.
This is the component that decides whether a pressure-fed system works, and the
one where the interesting mistakes live. Three of them are structural enough to
be worth stating before any code.
**The ullage is not a fixed volume.** Liquid leaves, so the gas expands, so it
cools, so the pressurant demand is larger than "volume divided by density" says.
:class:`~feedtwin.vessels.volume.GasVolume` assumes a fixed volume and cannot be
reused unmodified; the expansion work term is what this module adds.
**The liquid's state variables are not the gas's.** The ullage is tracked as
``(mass, internal energy)`` because a real gas's energy balance is only exact in
``u``. The liquid is tracked as ``(mass, temperature)`` -- the opposite choice,
for the opposite reason: liquid density is about 180x less sensitive to pressure
than a gas's, so recovering pressure from ``(rho, u)`` amplifies any error in
density by that factor. Each phase gets the state pair its physics is
well-conditioned in. Forcing one convention on both is tidier and wrong.
**Ullage collapse shows up as pressurant demand, not as a pressure drop.** With
a regulator holding tank pressure, heat lost to the liquid is made up by more
gas, which drains the COPV faster, which lowers regulator inlet, which moves the
outlet through the supply-pressure coefficient. Collapse and droop are one loop.