STAR
Cal STAR — firmware, DAQ server, and engine design
Loading...
Searching...
No Matches
test_cstar_fluid_props_plumbing Namespace Reference

Functions

 _solver ()
 test_both_streams_get_the_configs_liquid_properties ()
 test_no_vaporization_property_is_assumed_on_the_6500N (monkeypatch)

Detailed Description

The c* vaporization march gets the config's own liquid properties, for BOTH propellants.

The chamber solver used to pass only four fuel keys with RP-1 fallbacks (boiling point 489 K,
latent heat 300 kJ/kg, MW 170) and no oxidizer properties at all, so the march took LOX as
vaporized at the face and the fuel's cp and injection temperature as assumed values.

Function Documentation

◆ _solver()

test_cstar_fluid_props_plumbing._solver ( )
protected

◆ test_both_streams_get_the_configs_liquid_properties()

test_cstar_fluid_props_plumbing.test_both_streams_get_the_configs_liquid_properties ( )

Definition at line 18 of file test_cstar_fluid_props_plumbing.py.

References _solver().

◆ test_no_vaporization_property_is_assumed_on_the_6500N()

test_cstar_fluid_props_plumbing.test_no_vaporization_property_is_assumed_on_the_6500N ( monkeypatch)

Definition at line 29 of file test_cstar_fluid_props_plumbing.py.

References _solver().