Variables | |
| float | WALL_MASS = 3.63 |
| float | WALL_CP = 897.0 |
A LOX load pushed in by a dewar (``Setup.dewar_psi``). The load is a flow through the fill line at the dewar's pressure less the tank's. Into a warm tank it boils on the wall and the vapour goes into the ullage -- the climb the stand shows during a chilldown -- and once the wall is at saturation it collects. Checked here against hand calculation and CoolProp, not against the session: the line against Crane's Cv relation and Clamond, the chill against ``h_fg`` per gram, and a zero dewar against the fixed-rate load it replaces.
|
protected |
Definition at line 171 of file test_dewar_load.py.
Referenced by test_a_fuel_load_ignores_the_dewar(), and test_no_dewar_is_the_fixed_rate_load_exactly().
|
protected |
Definition at line 238 of file test_dewar_load.py.
References _le4_session().
Referenced by test_a_chilling_tank_climbs_and_climbs_more_the_harder_the_dewar_pushes(), test_the_fill_cv_is_calibrated_to_the_stands_30_psig_chill(), and test_without_a_dewar_the_chill_vents_outside_the_ullage_as_before().
|
protected |
LE4's LOX tank vented through its top disconnect, the cart's valve beyond it (``test_pid_drawn_freely._le4_with_top_manifold``).
Definition at line 199 of file test_dewar_load.py.
References Setup.
Referenced by _chill(), test_a_disconnect_that_gives_its_own_cv_keeps_it(), test_a_skipped_chilldown_collects_at_once_where_a_chilling_one_does_not(), test_skipping_chilldown_leaves_a_storable_and_an_unknown_tank_alone(), and test_the_carts_vent_valve_sizes_an_unsized_gse_vent().
|
protected |
Definition at line 30 of file test_dewar_load.py.
Referenced by test_a_chilling_tank_vents_its_boil_off_not_air_the_floor_puts_back(), test_a_clean_line_pours_tens_of_times_what_the_valve_lets_through(), test_a_fuel_load_ignores_the_dewar(), test_a_full_tank_takes_no_more(), test_into_a_warm_tank_every_gram_boils_into_the_ullage(), test_no_dewar_is_the_fixed_rate_load_exactly(), test_nothing_flows_back_into_the_dewar(), test_once_the_wall_is_cold_the_load_collects(), test_the_fill_line_is_crane_and_clamond(), and test_the_last_of_the_wall_boils_and_the_rest_collects().
| None test_dewar_load.test_a_chilling_tank_climbs_and_climbs_more_the_harder_the_dewar_pushes | ( | ) |
The stand: a LOX tank rises while it chills, as far as the vent makes it, and the dewar's pressure sets the pour.
Definition at line 271 of file test_dewar_load.py.
References _chill().
| None test_dewar_load.test_a_chilling_tank_vents_its_boil_off_not_air_the_floor_puts_back | ( | ) |
The vent of a tank chilling under its own boil-off carries that boil-off. Split by mass share alone, the vent took the tank's air down to the floor (an atmosphere's worth, which the pressurant keeps because it carries the ullage's heat capacity) and the floor put it straight back: on LE4, ~3 g/s of air that did not exist and 0.2 kg over a load, booked as a guard. The vent here carries what the dewar boils into the ullage; the guards must book next to nothing of it.
Definition at line 305 of file test_dewar_load.py.
References _sim().
| None test_dewar_load.test_a_clean_line_pours_tens_of_times_what_the_valve_lets_through | ( | ) |
The reason the dewar valve is calibrated rather than left open: a bare 3/8 in line from 100 psig pours ~0.7 kg/s.
Definition at line 85 of file test_dewar_load.py.
References _sim().
| None test_dewar_load.test_a_disconnect_that_gives_its_own_cv_keeps_it | ( | ) |
Turned on against a drawing that sizes the vent, the setup changes nothing.
Definition at line 261 of file test_dewar_load.py.
References _le4_session().
| None test_dewar_load.test_a_fuel_load_ignores_the_dewar | ( | ) |
The dewar is a cryogen's. With it on, ethanol still pours at its rate.
Definition at line 187 of file test_dewar_load.py.
References _advance(), and _sim().
| None test_dewar_load.test_a_full_tank_takes_no_more | ( | ) |
Definition at line 163 of file test_dewar_load.py.
References _sim().
| None test_dewar_load.test_a_skipped_chilldown_collects_at_once_where_a_chilling_one_does_not | ( | ) |
Nobody rehearsing waits out the minutes a dewar load spends on the wall (the team, 2026-10-08). Skipped, the wall is where the chill would have left it and the next seconds of the pour collect; not skipped, they boil.
Definition at line 334 of file test_dewar_load.py.
References _le4_session().
| None test_dewar_load.test_into_a_warm_tank_every_gram_boils_into_the_ullage | ( | ) |
Chilling: nothing collects, the vapour goes into the ullage (where only the vent can take it out), and the wall gives up h_fg per gram -- h_fg from CoolProp here, not from the model.
Definition at line 102 of file test_dewar_load.py.
References _sim().
| None test_dewar_load.test_no_dewar_is_the_fixed_rate_load_exactly | ( | ) |
Zero dewar pressure: the load before this existed, wanted / fill_seconds.
Definition at line 177 of file test_dewar_load.py.
References _advance(), and _sim().
| None test_dewar_load.test_nothing_flows_back_into_the_dewar | ( | ) |
Definition at line 96 of file test_dewar_load.py.
References _sim().
| None test_dewar_load.test_once_the_wall_is_cold_the_load_collects | ( | ) |
Definition at line 130 of file test_dewar_load.py.
References _sim().
| None test_dewar_load.test_skipping_chilldown_leaves_a_storable_and_an_unknown_tank_alone | ( | ) |
Definition at line 370 of file test_dewar_load.py.
References _le4_session().
| None test_dewar_load.test_the_carts_vent_valve_sizes_an_unsized_gse_vent | ( | ) |
Definition at line 253 of file test_dewar_load.py.
References _le4_session().
| None test_dewar_load.test_the_fill_cv_is_calibrated_to_the_stands_30_psig_chill | ( | ) |
The default Cv (0.019, the team 2026-10-08) tops LE4 out near the stand's ~30 psig. 0.013 did until the vent stopped taking back air the pressurant floor re-created (2026-10-06); it then peaked near 21. The calibration was made against the plain valve's old gas law, which passed up to 1.5x IEC just short of the choke -- where a chilling tank's vent runs. With the vent priced by IEC 60534-2-1 (R035) the same 0.019 peaks at 44.75 psig on this stand (0.014: 33.7; 0.012: 28.6; 0.010: 23.2). LE4 (3) as uploaded does not move (16.4 -> 16.5 psia at 140 s of Ox Fill). Recalibrating is the team's call; strict, so it turns red when they do.
Definition at line 285 of file test_dewar_load.py.
References _chill().
| None test_dewar_load.test_the_fill_line_is_crane_and_clamond | ( | ) |
Liquid through the line: drop = (f L/D + K + 1) rho v^2 / 2, with K from Crane's Cv relation K = 891 d^4 / Cv^2 (d in inches) and f Clamond at the Reynolds number of the answer.
Definition at line 67 of file test_dewar_load.py.
References _sim().
| None test_dewar_load.test_the_last_of_the_wall_boils_and_the_rest_collects | ( | ) |
A step that brings the wall down to saturation splits: what the wall's remaining heat boils, and the rest in the liquid.
Definition at line 138 of file test_dewar_load.py.
References _sim().
| None test_dewar_load.test_without_a_dewar_the_chill_vents_outside_the_ullage_as_before | ( | ) |
Definition at line 300 of file test_dewar_load.py.
References _chill().
| float test_dewar_load.WALL_CP = 897.0 |
Definition at line 27 of file test_dewar_load.py.
| float test_dewar_load.WALL_MASS = 3.63 |
Definition at line 26 of file test_dewar_load.py.