STAR
Cal STAR — firmware, DAQ server, and engine design
|
Functions | |
| ComponentInstance | body (**object overrides) |
| Manifold | copv_manifold () |
| None | test_only_flow_ports_carry_mass () |
| None | test_an_instrument_port_reads_plenum_pressure_exactly () |
| None | test_a_conditional_port_is_a_stub_while_shut () |
| None | test_port_loss_is_turn_plus_fitting () |
| None | test_a_straight_through_port_does_not_turn () |
| None | test_loss_is_symmetric_in_flow_direction () |
| None | test_smaller_ports_cost_more () |
| None | test_derived_turn_K_grows_as_the_port_narrows () |
| None | test_a_manifold_refuses_to_be_one_branch () |
| None | test_expansion_produces_one_branch_per_port () |
| None | test_expansion_requires_a_node_for_every_port () |
| None | test_expansion_rejects_an_unknown_port () |
| None | test_duplicate_ports_are_rejected () |
| None | test_a_port_wider_than_its_plenum_is_flagged () |
| None | test_a_one_outlet_manifold_is_flagged_as_a_fitting () |
| None | test_a_healthy_manifold_is_clean () |
Variables | |
| GAS = FlowConditions(rho=39.0, mu=1.78e-5, p_upstream=4500 * 6894.757293168361) | |
Manifolds: a plenum with ports, and the three kinds of port. The team's COPV manifold is the worked example -- one inlet, a transducer tap, a relief valve, a fill quick-disconnect and the regulator feed -- because it is the case that motivated the dead-end peeling in Phase 04 and the port taxonomy here.
| ComponentInstance test_manifold.body | ( | **object | overrides | ) |
Definition at line 32 of file test_manifold.py.
Referenced by copv_manifold(), test_a_one_outlet_manifold_is_flagged_as_a_fitting(), test_a_port_wider_than_its_plenum_is_flagged(), test_duplicate_ports_are_rejected(), and test_smaller_ports_cost_more().
| Manifold test_manifold.copv_manifold | ( | ) |
One inlet, four takeoffs. The real hardware.
Definition at line 41 of file test_manifold.py.
References body().
Referenced by test_a_conditional_port_is_a_stub_while_shut(), test_a_healthy_manifold_is_clean(), test_a_manifold_refuses_to_be_one_branch(), test_a_straight_through_port_does_not_turn(), test_an_instrument_port_reads_plenum_pressure_exactly(), test_expansion_produces_one_branch_per_port(), test_expansion_rejects_an_unknown_port(), test_expansion_requires_a_node_for_every_port(), test_loss_is_symmetric_in_flow_direction(), test_only_flow_ports_carry_mass(), and test_port_loss_is_turn_plus_fitting().
| None test_manifold.test_a_conditional_port_is_a_stub_while_shut | ( | ) |
A shut relief and a capped port are topologically identical. Physically they are nothing alike, which is why the kind is declared. This test pins the declaration, not the behaviour -- the behaviour is the same.
Definition at line 75 of file test_manifold.py.
References copv_manifold().
| None test_manifold.test_a_healthy_manifold_is_clean | ( | ) |
Definition at line 224 of file test_manifold.py.
References check(), and copv_manifold().
| None test_manifold.test_a_manifold_refuses_to_be_one_branch | ( | ) |
The failure that stops port losses from silently vanishing.
Definition at line 146 of file test_manifold.py.
References copv_manifold().
| None test_manifold.test_a_one_outlet_manifold_is_flagged_as_a_fitting | ( | ) |
Definition at line 212 of file test_manifold.py.
References body().
| None test_manifold.test_a_port_wider_than_its_plenum_is_flagged | ( | ) |
Definition at line 203 of file test_manifold.py.
References body().
| None test_manifold.test_a_straight_through_port_does_not_turn | ( | ) |
An in-line outlet is not a side tapping and should not be charged as one.
Definition at line 104 of file test_manifold.py.
References copv_manifold().
| None test_manifold.test_an_instrument_port_reads_plenum_pressure_exactly | ( | ) |
A transducer tap has no flow, so it has no drop. Ever.
Definition at line 64 of file test_manifold.py.
References copv_manifold().
| None test_manifold.test_derived_turn_K_grows_as_the_port_narrows | ( | ) |
Rung 6 of the K ladder: derived from the area ratio when nothing better.
Definition at line 136 of file test_manifold.py.
| None test_manifold.test_duplicate_ports_are_rejected | ( | ) |
Definition at line 192 of file test_manifold.py.
References body().
| None test_manifold.test_expansion_produces_one_branch_per_port | ( | ) |
Definition at line 153 of file test_manifold.py.
References copv_manifold().
| None test_manifold.test_expansion_rejects_an_unknown_port | ( | ) |
Definition at line 180 of file test_manifold.py.
References copv_manifold().
| None test_manifold.test_expansion_requires_a_node_for_every_port | ( | ) |
Including the instrument ones -- that is how a tap reads plenum pressure.
Definition at line 170 of file test_manifold.py.
References copv_manifold().
| None test_manifold.test_loss_is_symmetric_in_flow_direction | ( | ) |
A manifold port does not care which way the gas goes through it.
Definition at line 113 of file test_manifold.py.
References copv_manifold().
| None test_manifold.test_only_flow_ports_carry_mass | ( | ) |
Definition at line 58 of file test_manifold.py.
References copv_manifold().
| None test_manifold.test_port_loss_is_turn_plus_fitting | ( | ) |
Definition at line 91 of file test_manifold.py.
References copv_manifold().
| None test_manifold.test_smaller_ports_cost_more | ( | ) |
Quartic in bore: halving a port is 16x the loss at the same mass flow.
Definition at line 126 of file test_manifold.py.
References body().
| test_manifold.GAS = FlowConditions(rho=39.0, mu=1.78e-5, p_upstream=4500 * 6894.757293168361) |
Definition at line 29 of file test_manifold.py.