| str | TABLE = Path(__file__).resolve().parents[1] / "copv" / "n2_Z_lookup.csv" |
copv/n2_Z_lookup.csv covers the pressures a COPV holds, not only a propellant tank's. The table stopped at 8.3 MPa; RegularGridInterpolator(fill_value=None) extrapolates linearly past it, so the COPV solvers read Z 1.039 at 26 MPa and 300 K where CoolProp gives 1.105. On the LE4 (3) stand's 1.312 kg in 4.619 L that put the charge at 3810 psia instead of 4141 (CoolProp, 300 K, 284 kg/m3), and shifted every COPV sizing in the Time-Series panel and Layer 2 by the same few per cent. Extended to 60 MPa from CoolProp, the rows inside the old range untouched.
| test_n2_z_table.interp | ( | ) |
Definition at line 20 of file test_n2_z_table.py.
| test_n2_z_table.test_copv_pressures_read_coolprop_not_an_extrapolation | ( | interp, | |
| T, | |||
| P ) |
Definition at line 27 of file test_n2_z_table.py.
| test_n2_z_table.test_the_tank_range_is_unchanged | ( | interp | ) |
A propellant-tank state (300 K, 5 MPa) still reads the original grid.
Definition at line 36 of file test_n2_z_table.py.
| str test_n2_z_table.TABLE = Path(__file__).resolve().parents[1] / "copv" / "n2_Z_lookup.csv" |
Definition at line 16 of file test_n2_z_table.py.