STAR
Cal STAR — firmware, DAQ server, and engine design
|
Functions | |
| test_eta_cstar_is_the_solvers_not_a_constant () | |
Variables | |
| float | PSI = 6894.757 |
The coupled time-series path reports the chamber solve's c* and eta_c*, not an assumed 0.85. runner.evaluate_arrays_with_time used to overwrite the time-varying solver's results with cstar_ideal = cstar_actual / 0.85, which set eta_c* to exactly 0.85 at every step (the Time-Series tab and Layer 2/3 read it).
| test_time_series_keeps_solver_cstar.test_eta_cstar_is_the_solvers_not_a_constant | ( | ) |
Definition at line 13 of file test_time_series_keeps_solver_cstar.py.
| float test_time_series_keeps_solver_cstar.PSI = 6894.757 |