The time-varying solve's wall, geometry and bookkeeping (TH-6, TH-8, TH-9, CN-7, TH-12, TH-2).
What each test guards, and what the code did before:
* the nozzle exit stayed put only on paper: it grew at the chamber liner's rate even with
``nozzle_ablative: false`` (eps rose 10 % over the burn);
* t = 0 rebuilt the chamber as a full-bore cylinder of cg.length (L* 1.08 for a 1.00 design);
* thrust used the post-step throat while Pc was solved on the pre-step one;
* the graphite surface was the caller's 2000 K guess and the insert conducted steadily into a
300 K sink, so a 3 mm and a 12 mm insert burned identically;
* the state carried a 2 GW/m^2 "nozzle heat flux", an 86,000 K nozzle wall and 3e7 K case.
|
protected |
Definition at line 32 of file test_time_varying_thermal.py.
|
protected |
Definition at line 36 of file test_time_varying_thermal.py.
Referenced by burn(), test_a_thinner_insert_runs_hotter_and_recedes_faster(), and test_exit_recedes_when_the_nozzle_is_ablative().
| test_time_varying_thermal.burn | ( | ) |
Definition at line 46 of file test_time_varying_thermal.py.
References _series().
| test_time_varying_thermal.test_a_thinner_insert_runs_hotter_and_recedes_faster | ( | ) |
Definition at line 108 of file test_time_varying_thermal.py.
References _series().
| test_time_varying_thermal.test_exit_does_not_recede_on_a_non_ablative_nozzle | ( | burn | ) |
Definition at line 51 of file test_time_varying_thermal.py.
| test_time_varying_thermal.test_exit_recedes_when_the_nozzle_is_ablative | ( | ) |
Definition at line 61 of file test_time_varying_thermal.py.
References _series().
| test_time_varying_thermal.test_legacy_geometry_helper_grows_from_the_declared_volume | ( | ) |
The non-coupled path's helper: a micron of recession must not jump the volume to a full-bore cylinder of cg.length (+8 % on this chamber).
Definition at line 163 of file test_time_varying_thermal.py.
| test_time_varying_thermal.test_liner_waits_for_its_ablation_temperature | ( | burn | ) |
The cold liner first has to heat to its ablation temperature -- semi-infinite onset t = (pi/4) k rho c (T_abl - T0)^2 / q^2, a few tenths of a second here -- so the first 0.25 s recedes far less than steady ablation would; by 2 s it ablates at the Landau rate.
Definition at line 120 of file test_time_varying_thermal.py.
| test_time_varying_thermal.test_soak_back_after_shutdown | ( | ) |
Definition at line 150 of file test_time_varying_thermal.py.
| test_time_varying_thermal.test_solver_reports_the_solved_efficiency | ( | ) |
Definition at line 91 of file test_time_varying_thermal.py.
| test_time_varying_thermal.test_state_is_physical | ( | burn | ) |
Definition at line 138 of file test_time_varying_thermal.py.
| test_time_varying_thermal.test_t0_geometry_is_the_design | ( | burn | ) |
Definition at line 68 of file test_time_varying_thermal.py.
| test_time_varying_thermal.test_thrust_is_computed_on_the_geometry_pc_was_solved_on | ( | burn | ) |
Definition at line 75 of file test_time_varying_thermal.py.
| test_time_varying_thermal.CFG = os.path.join(ROOT, "configs", "ethalox_6500N.yaml") |
Definition at line 26 of file test_time_varying_thermal.py.
| float test_time_varying_thermal.P_TANK = 584.27 * PSI |
Definition at line 28 of file test_time_varying_thermal.py.
| float test_time_varying_thermal.PSI = 6894.757293168361 |
Definition at line 27 of file test_time_varying_thermal.py.
| test_time_varying_thermal.ROOT = os.path.dirname(os.path.dirname(os.path.abspath(__file__))) |
Definition at line 25 of file test_time_varying_thermal.py.