STAR
Cal STAR — firmware, DAQ server, and engine design
Loading...
Searching...
No Matches
test_timeseries_injector_dp Namespace Reference

Classes

class  _Runner

Functions

 test_injector_drops_reach_the_response ()
 test_a_point_without_the_key_is_missing_not_zero ()

Variables

float PSI = 6894.76

Detailed Description

The Time-Series run reports each point's injector pressure drop, as forward mode does.

The per-point diagnostics a run collects are the injector closure's, keyed
``delta_p_injector_O`` / ``_F`` (engine/core/injectors/impinging.py, pintle.py). The Time-Series
router read ``delta_P_injector_*`` (capital P), found nothing at any point, and left
``delta_P_injector_O_psi`` out of every response -- so PressureCurveChart's "Injector Pressure Drops
vs Time" never rendered and the plotter offered a series that was never there.

Function Documentation

◆ test_a_point_without_the_key_is_missing_not_zero()

test_timeseries_injector_dp.test_a_point_without_the_key_is_missing_not_zero ( )

Definition at line 54 of file test_timeseries_injector_dp.py.

◆ test_injector_drops_reach_the_response()

test_timeseries_injector_dp.test_injector_drops_reach_the_response ( )

Definition at line 42 of file test_timeseries_injector_dp.py.

Variable Documentation

◆ PSI

float test_timeseries_injector_dp.PSI = 6894.76

Definition at line 19 of file test_timeseries_injector_dp.py.