| float | PSI = 6894.76 |
The Time-Series run reports each point's injector pressure drop, as forward mode does. The per-point diagnostics a run collects are the injector closure's, keyed ``delta_p_injector_O`` / ``_F`` (engine/core/injectors/impinging.py, pintle.py). The Time-Series router read ``delta_P_injector_*`` (capital P), found nothing at any point, and left ``delta_P_injector_O_psi`` out of every response -- so PressureCurveChart's "Injector Pressure Drops vs Time" never rendered and the plotter offered a series that was never there.
| test_timeseries_injector_dp.test_a_point_without_the_key_is_missing_not_zero | ( | ) |
Definition at line 54 of file test_timeseries_injector_dp.py.
| test_timeseries_injector_dp.test_injector_drops_reach_the_response | ( | ) |
Definition at line 42 of file test_timeseries_injector_dp.py.
| float test_timeseries_injector_dp.PSI = 6894.76 |
Definition at line 19 of file test_timeseries_injector_dp.py.