STAR
Cal STAR — firmware, DAQ server, and engine design
|
Public Member Functions | |
| str | name (self) |
| float | heat_rate (self, float area, float gas_temperature, float liquid_temperature, LiquidThermal liquid, float elapsed) |
How much heat the ullage loses to the liquid surface, and when.
Definition at line 97 of file collapse.py.
| float feedtwin.vessels.collapse.CollapseModel.heat_rate | ( | self, | |
| float | area, | ||
| float | gas_temperature, | ||
| float | liquid_temperature, | ||
| LiquidThermal | liquid, | ||
| float | elapsed ) |
Heat leaving the ullage [W]. Positive means the gas is cooling.
Args:
area: Interfacial area [m^2] -- the tank's cross-section at the
surface, which a head geometry makes a function of fill.
gas_temperature: Bulk ullage temperature [K].
liquid_temperature: Bulk liquid temperature [K].
liquid: Liquid thermal properties.
elapsed: Contact time since the interface was last reset [s].
Definition at line 103 of file collapse.py.
| str feedtwin.vessels.collapse.CollapseModel.name | ( | self | ) |
Definition at line 101 of file collapse.py.