STAR
Cal STAR — firmware, DAQ server, and engine design
|
Functions | |
| object | _measured (str tag) |
| None | _ethanol (Network net, *tuple[str, float|None] nodes) |
| None | test_a_sweep_that_brackets_the_answer_solves () |
| None | test_a_capped_measured_stub_back_fills_without_raising () |
| None | test_off_the_ends_is_continued_quadratically_and_flagged () |
Variables | |
| float | PSI = 6894.757293168361 |
| BENCH | |
A measured component whose flow-bench sweep does not start at zero. Flow benches rarely measure at zero flow, and a Newton solve starts every branch at 1 g/s and probes past the top of any sweep. A measurement that brackets the operating point must solve, the excursions off its ends are continued (``dp ~ mdot^2``, the law the curve measures) and flagged, and a solve asked not to raise never raises.
|
protected |
Definition at line 38 of file test_measured_off_curve.py.
Referenced by test_a_capped_measured_stub_back_fills_without_raising(), test_a_sweep_that_brackets_the_answer_solves(), and test_off_the_ends_is_continued_quadratically_and_flagged().
|
protected |
Definition at line 30 of file test_measured_off_curve.py.
Referenced by test_a_capped_measured_stub_back_fills_without_raising(), test_a_sweep_that_brackets_the_answer_solves(), and test_off_the_ends_is_continued_quadratically_and_flagged().
| None test_measured_off_curve.test_a_capped_measured_stub_back_fills_without_raising | ( | ) |
A capped stub is back-filled at exactly zero flow, off the curve.
Definition at line 61 of file test_measured_off_curve.py.
References _ethanol(), and _measured().
| None test_measured_off_curve.test_a_sweep_that_brackets_the_answer_solves | ( | ) |
20 psi across a sweep of 2-32 psi over 0.05-0.2 kg/s: inside the curve (8 psi at 0.1, 32 at 0.2, so about 0.158 kg/s). The first iterate at 1 g/s used to raise off the bottom of the curve and fail the solve.
Definition at line 46 of file test_measured_off_curve.py.
References _ethanol(), _measured(), and BENCH.
| None test_measured_off_curve.test_off_the_ends_is_continued_quadratically_and_flagged | ( | ) |
Above the sweep the loss keeps its measured ``mdot^2`` shape, and the diagnostics say the point was not measured.
Definition at line 83 of file test_measured_off_curve.py.
References _ethanol(), _measured(), and BENCH.
| test_measured_off_curve.BENCH |
Definition at line 21 of file test_measured_off_curve.py.
Referenced by test_a_sweep_that_brackets_the_answer_solves(), and test_off_the_ends_is_continued_quadratically_and_flagged().
| float test_measured_off_curve.PSI = 6894.757293168361 |
Definition at line 20 of file test_measured_off_curve.py.